Introduction to the start-up and suspension of Tangshan catalytic combustion equipment

2021-10-30

visits:

Introduction to Starting and Stopping Tangshan Catalytic Combustion Equipment
Before starting the machine, preheat the catalyst with fresh air, and then preheat the exhaust gas to above 250 degrees before entering the catalytic chamber; Before shutting down the system, cut off the exhaust gas, continue heating the catalyst, introduce fresh air, keep it warm for 0.5 hours, and then cut off the power supply.
2. When using the catalyst, please strictly follow the instructions for the catalyst usage conditions. The factors that affect the lifespan of catalysts include the pre-treatment status of exhaust gas, namely the cleanliness of the exhaust gas, the temperature of the catalytic chamber, the toxicity of halogens and catalysts, and the operating procedures of the catalytic combustion device.
When catalysts are used for catalytic combustion, they require high heat resistance and anti toxicity. Due to the unstable concentration, flow rate, and composition of organic waste gases during catalytic combustion, the adaptability of catalysts is relatively high, so catalytic combustion generally does not require very strict operating conditions. The catalyst combustion process has a high operating airspeed, and the airflow has a significant impact on the catalyst. At the same time, the bed temperature will rise and fall, which will cause thermal shrinkage and easily damage the catalyst carrier. Therefore, the catalyst should have high mechanical strength and good performance. Resistance to thermal shrinkage.
If necessary, please feel free to contact the catalytic combustion manufacturer of Tangshan Lantian Aoyu at any time.